Apura s.r.l. — Italian Pure Excellence

Water That Reports on Itself

Apura s.r.l. builds online analysers that measure hardness, alkalinity, iron, silica and disinfectant residual continuously — and act on the result. Designed and manufactured in Italy under ISO 9001:2015.

Ω DUROMAT amperometric analyser, showing controller, flow cell and probe inside a wall-mount enclosure
Ω DUROMAT® amperometric analyser
5Measured parameters
IP 56Enclosed protection
4–20 mAPlus MODBUS & relays
10,000Analyses per bottle
Apura in the Process

You Cannot Control What You Cannot See

Industrial pre-treatment and reverse osmosis water — how Apura online analysers give you real-time data. Hover any monitor for the instrument behind it, or select it to jump straight to the product.

Concentrate to drain Feed tank Media filter Carbon filter Softener REGENERATING Antiscalant Guard filter 5 µm HP pump RO membranes Scaling risk Permeate tank To process
Raw water intake
0.18mg/l Fe
Iron
DUROMAT® Professional Fe Colorimetric on-line iron analyser. Catches iron in borehole or river feed — the fouling that shortens membrane life long before pressure drop shows it. Colorimetric · 0.01–0.5 or 0.2–10 mg/l
Carbon filter outlet
0.02mg/l Cl₂
Free chlorine
Ω DUROMAT® amperometric Membrane-covered amperometric probe for free chlorine, chlorine dioxide or ozone. Proves the carbon bed is still dechlorinating — one oxidant breakthrough damages a polyamide membrane permanently. Amperometric · probe 0.01–2 ppm
Softener outlet
0.24ppm CaCO₃
Total hardness
DUROMAT® Professional On-line colorimetric hardness analyser with programmable pre-alarm and alarm relays. Detects resin exhaustion at the outlet and triggers regeneration before hardness ever reaches the membranes. Colorimetric · 0.22–534 ppm CaCO₃
RO permeate
12.4µS/cm
Conductivity & pH
Apura panel instruments Panel and DIN-rail transmitters for pH, conductivity and temperature. Rising permeate conductivity is the first sign of a failing element or a leaking O-ring. 48 × 96 mm panel · 4–20 mA
Treated water to process
0.06mg/l SiO₂
Reactive silica
DUROMAT® Diamond Silica Reactive silica analyser. The final quality gate for high-purity duty — semiconductor rinse water, boiler make-up and turbine steam, where silica carries over and deposits where you cannot clean it. Colorimetric · 0.02–10.0 mg/l

Scroll the diagram sideways to see the full line →

Five Apura measuring points on one line — every stage watched continuously, no grab samples, no waiting for the lab.

Within limits Drifting Alarm Select a monitor to open the instrument
Why Continuous Measurement

A Grab Sample Describes One Minute of the Day

Manual testing catches a problem after it has already passed through the system. An online analyser measures on a set interval, holds the result against a threshold, and switches a relay before the damage reaches the next stage.

01
Protect What Sits Downstream

Hardness breakthrough after a softener scales a boiler or fouls an RO membrane. Measuring at the softener outlet raises the alarm while the fix is still cheap.

02
Regenerate on Condition, Not a Clock

Triggering regeneration from an actual hardness reading rather than a timer saves salt, water and the hours spent running a cycle that was not needed.

03
Keep a Record You Can Defend

Results, errors and timestamps write to SD card. When an auditor or a customer asks what the water was doing last Tuesday, the log answers.

Inside a Colorimetric Analyser

Every Reading Is a Full Wet-Chemistry Cycle

The DUROMAT® colorimetric range does not estimate from a sensor drift curve. It runs a complete laboratory method on each measurement, then flushes and waits for the next one.

01

Admit Sample

The inlet solenoid valve opens and sample water enters the measuring chamber.

02

Wash

The chamber is flushed for a settable time, clearing the previous sample.

03

Zero Test

Water transparency is checked to establish the optical zero point for this sample.

04

Dose Reagent

A peristaltic pump meters the indicator into the chamber.

05

Read & Act

The result displays, drives the 4–20 mA output and switches any relay whose threshold is crossed.

06

Flush & Wait

A final wash leaves the chamber clean until the next timed, volumetric, manual or external start.

If a reading only just exceeds the maximum, the analyser can repeat the analysis before raising an alarm — so a single anomalous sample does not trip a plant. Intervals are programmable from 3 to 9,999 minutes.

DUROMAT® Colorimetric Analysers

Three Analysers, One Method

The same wet-chemistry cycle and the same chassis. What changes is the parameter each one measures — start from what you need to control.

ModelMeasuresRangeOutputsBest suited to
DUROMAT® ProfessionalHardness & alkalinity Total hardness, residual hardness, alkalinity 0.22–534 ppm CaCO₃
0.012–30 °dH
4 relays · 4–20 mA · SD · MODBUS Softener supervision, RO feed protection, boiler houses
DUROMAT® Professional FeIron variant Iron (Fe²⁺/Fe³⁺) 0.01–0.5 mg/l
or 0.2–10 mg/l
4 relays · 4–20 mA · SD · MODBUS RTU Verifying iron removal ahead of softening or RO
DUROMAT® Diamond SilicaThree-reagent Reactive silica (SiO₂) 0.02–10.0 mg/l
extendable via dilution
4 relays · 4–20 mA · SD card High-pressure boiler feedwater and demineralised polish
ApuraDUROMAT Professional analyser with graphic display and reagent bottle
DUROMAT® Professional
Hardness & alkalinity

The analyser for softener supervision and RO feed protection. Four relays and MODBUS make it the model for plant rooms that report upward.

  • Fifteen reagent options set the working range
  • Relays for alarm, pre-alarm, fault and reagent-empty
  • MODBUS standard, CANBUS optional
  • Roughly 10,000 analyses per 500 ml bottle
Datasheet PDF, 379 KB
ApuraDUROMAT Professional Fe iron analyser, same chassis with iron reagent
DUROMAT® Professional Fe
Iron

The same chassis and cycle, configured for iron. Confirms an iron removal filter is still doing its job before the residue reaches resin or membrane.

  • Low range 0.01–0.5 mg/l, high range 0.2–10 mg/l
  • Dilution unit to 1:10 for higher concentrations
  • MODBUS RTU, CANBUS optional
  • Coolers available for sample up to 200 °C
Datasheet PDF, 390 KB
ApuraDUROMAT Diamond Silica analyser cabinet with three peristaltic pumps and reagent bottles
DUROMAT® Diamond Silica
Reactive silica

Silica passes a softener untouched, carries over with steam and deposits on turbine blades where nothing dissolves it off. This is the gate that catches it.

  • Reagents A, B and C on separate peristaltic pumps
  • IP 56 cabinet, 595 × 420 × 210 mm, 8.6 kg
  • Sample 5–40 °C at 0.2–6 bar
  • Pre-alarm and alarm set points
Datasheet PDF, 416 KB
Ω DUROMAT® Amperometric

One Analyser, Seven Disinfectants

The measurement is set by the probe you fit, not by the instrument you buy. Change the parameter later by changing the probe.

Ω DUROMAT analyser with amperometric probe and transparent flow cell mounted in an enclosure
Ω DUROMAT® with flow cell and probe
Free chlorine
0.01–2 / 20 / 200 ppm
Total chlorine
0.01–2 / 20 ppm
Chlorine dioxide
0.005–2 / 0.05–20 ppm
Chlorite
0.005–2 ppm
Peracetic acid
0.5–200 / 5–2,000 ppm
Ozone
0.005–2 / 0.05–20 ppm
Bromine
0.05–2 ppm
Hydrogen peroxide
Probe dependent

pH compensation for free chlorine

Free chlorine efficacy falls as pH rises. The compensated version reads the pH alongside and corrects the residual figure, so the number on the display reflects the disinfection you actually have.

Seawater and surfactant-resistant probes

Chlorine and chlorine dioxide probes are available in variants that hold up in seawater and in water carrying surfactants — relevant for coastal intakes and wash-down streams.

3 relays4–20 mAIP 56 boxedProbe cable to 10 m
Datasheet PDF, 527 KB
Applications

Chosen by What Fails When the Water Drifts

Boiler Feedwater

Hardness carryover scales tubes and silica deposits on turbine blades. Both are far cheaper to measure than to remove.

Professional · Diamond Silica
Softener Supervision

Confirm the resin is still working and regenerate on an actual reading instead of a timer.

Professional
RO Pre-Treatment

Hardness and iron reaching the membrane shorten its life. Measuring at the feed protects the asset behind it.

Professional · Professional Fe
Cooling Towers

Continuous disinfectant residual keeps biological control inside its window rather than swinging above and below it.

Ω DUROMAT
Potable Water & Buildings

Residual monitoring across hotel, hospital and campus distribution, with pH-compensated free chlorine.

Ω DUROMAT
Food and Beverage

Process water quality control and verification of peracetic acid concentration on clean-in-place lines.

Ω DUROMAT · Professional
Semiconductor Fabrication

Silica and conductivity monitoring on demineralised and polished loops where specification is tight.

Diamond Silica
Swimming Pools & Leisure

Free chlorine, chlorine dioxide, bromine or ozone residual, with the probe matched to the treatment in use.

Ω DUROMAT

Tell us what your water is doing

Send us your parameter, expected range and sample conditions — temperature, pressure and where the tapping point sits — and we will come back with the model and reagent that fit.

✉ Contact Us Back to Mainpage